Skip to main content Skip to search Skip to main navigation

MyoHand VariPlus Speed with Threaded Stud Wrist Connection

Part # Description  

Product information

The MyoHand VariPlus Speed with threaded stud wrist connection is suitable for all amputation levels except wrist disarticulation. It combines the mechanical characteristics of the SensorHand Speed and the control options of the DMC VariPlus System Electric Greifer. Thanks to the high gripping strength (approx. 100 N) and speed (up to 300 mm/s), objects can be gripped quickly and precisely. This hand has a central coaxial plug connection, automatic shut-off electronics and integrated on-off switch, low-friction bevel gear, positive back lock and system inner hand. An integrated slip clutch allows the hand to be opened in case of power supply or myoelectric control failure. With the 757T13 MyoSelect, a total of 6 different programs can be selected and adapted according to patient indications. This permits optimum adaptation to the needs and abilities of the prosthesis wearer.

  • The MyoHand VariPlus Speed can be operated with the 757B35=* MyoEnergy Integral, the 757B20/757B21 EnergyPack or the 757B15 X-ChangePack
  • The following control modes can be selected with the 757T13 MyoSelect:
  • DMC plus
  • AutoControl LowInput
  • VarioControl
  • VarioDual
  • DigitalControl
  • DoubleChannel Control

Specifications

  • Amputation: Transhumeral, Transradial
  • Static Current (mA): 1
  • Operating Temperature (C): 0-70 degrees
  • Maximum Opening Width (mm): 100
  • Maximum Gripping Force (N): 100
  • Maximum Speed (mm/sec): 300
  • Device Weight: 0.97lbs (442 g)
HCPCS: L6882, L7007
Skip product gallery

Frequently Bought Together

Electrode Cable with Straight Plug and Connector

Electrode Cable with Straight Plug and Connector

Used to connect the electrodes in myoelectric systems to a:9E169 Coaxial Plug13E205 MyoRotronic9E369/9E370 4-in -1 LS Controller or 9E420 7-in-1 Controller13E190 Distributor or 10S7 Electric Wrist Rotator

Lamination Ring

Lamination Ring

Lamination ring for System Electric Hands or System Electric Greifers with lamination protection cover for bonding.

Standard Electrode

Standard Electrode

The 13E200 Myobock Electrode lessens sensitivity to low and high frequency interferences to minimize prostheses operation interruption and provide noise filtration.

Suction Socket Electrode

Suction Socket Electrode

Electrode cable connection with IDC termination, with 13E206 Electrode Accessories, without electrode cable. Creates an airtight seal between the inner socket and outer socket when embedded into a mounting suspension of elastic material. The Suction Socket Electrode also prevents sweat from penetrating between the outer and inner socket, preventing damage to the electrical and mechanical components caused by corrosion.The Suction Socket Electrode can not only be used for standard fittings, but is also suitable for application in suction sockets. Combining the suction socket electrode with a 12V10 Tube Valve for a suction socket creates a vacuum effect in the socket, ensuring optimal linkage between the residual limb and the socket.Shielding and filtering technologies largely protect the 13E202 Suction Socket Electrode against high frequency interference caused by cell phones, walkie-talkies, computers or anti-theft systems in shopping centers so that the correct function of the myoelectrically controlled prosthesis is not affected. The electrode contacts are made from pure titanium and are suitable for people with allergies.Includes:(1) 13E200 electrode(1) 13E80 adjustment tool(1) 13E191 casting template for inner socket(1) 13E192 lamination template(2) 507S15 lamination plate with bore(1) 13E201 electrode accessories for vacuum-formed inner sockets(2) 503F3 socket screw with Allen headThe following products are also required:13E129=* electrode cable

MyoEnergy Integral Power Supply System

MyoEnergy Integral Power Supply System

The MyoEnergy Integral 757B35=* is an integrated power supply system made up of several components. The charging receptacle enables battery contact, indicates the current charge status and serves to switch the prosthesis on and off and release it in an emergency. The communication cable with a 3-pin receptacle is used for the exchange of data. The supply cable establishes the connection between the battery and the respective prosthesis component. The battery consists of two cells with different capacities.Includes:Battery Lamination DummyCharging Receptacle Lamination DummyDrilling Template for Charging ReceptacleCharger must be ordered separately - 757L35 MyoCharge Integral

Battery Cable

Battery Cable

Battery cable for 757B20 and 757B21 series batteries.For connecting the 757Z185=1 or 757Z191=1 Battery Receptacle to 9E169 Coaxial Plug, 10S17 Electric Wrist Rotator or 13E205 MyoRotronic or the 13E190 or 13E190=150 distributor.Available in two lengths: 200 mm (13E188=200) or 600 mm (13E188=600)

Li-Ion Battery Charger

Li-Ion Battery Charger

757L20 Lithium-Ion Battery Charger provides:Simultaneous charging of one or two 757B20/757B21 EnergyPack batteries100 – 240 (automatic adjustment) V/ACFull charging of 757B20 in approximately 3.5 hoursFull charging of 757B21 in approximately 3.0 hoursThe case is made of impact-resistant plastic materialScope of delivery includes:ChargerIncludes 757L16-4 Main Adapter with interchangeable EU and US plugsThe 4X74 car adapter cable can be ordered separately

MyoWrist 2Act

MyoWrist 2Act

The MyoWrist 2Act 10V40 was developed especially for all variants of the Otto Bock System Electric Hands with the 8E41 Threaded Stud to maintain a low structural height for the whole system. Flexion and extension possible with 5 locking positions from -40° to +40° in 20° increments. Rotation is performed passively via the wrist lock. Active rotation is also possible in combination with the MyoRotronic 13E205.

MyoSkin Natural Glove for Men

MyoSkin Natural Glove for Men

The MyoSkin Natural Glove for men has a multi-layered design providing depth and a very vivid, natural appearance. Robust and easy to clean, the glove protects the prosthesis from dust, dirt and moisture. Designed for use with Myobock hands.Multilayered structure provides natural appearance and resilient prosthetic coveringDirt can be removed with water and soap, while tough stains can be cleaned with the 640F12 Ottobock Special CleanerColor scale 646M47 can be used for selectionMulti-Layered PVC provides depth effect for vivid, natural appearanceOuter translucent layer allows colored fibers to shine through producing luminous qualityTreated with a special surface treatment for easy clean-up

Cosmetic Glove for Women

Cosmetic Glove for Women

The Cosmetic Glove for Women is sized to fit, protect, and facilitate the movement of myoelectric terminal devices. Color scale 646M3 is used for matching glove color with patient’s skin tone.Applicable for protection of MyoBock terminal devicesAvailable in 18 skin shades

System Cosmetic Glove

System Cosmetic Glove

The System Cosmetic Glove is designed to protect MyoBock terminal devices. It has a natural appearance, durability, and is flexible to facilitate movement of myoelectric terminal devices.Applicable for protection of MyoBock terminal devicesAvailable for hand sizes 7 ¼, 7 ¾, 8 and 8 ¼Color scale 646M3 can be used for matching glove color with patient’s skin tone

EnergyPack

EnergyPack

757B20 EnergyPacks are:Available in colors: 4 (757B20, 757B21), 11 (757B20-1, 757B21-1), 15 (757B20-2, 757B21-2) and Black (757B20-3, 757B21-3)Appropriate for more active patients and SensorHand Speed usersTo be used only for MyoBock Adult SystemsDesigned utilizing Lithiom-Ion technology for longer life than NiCd batteryCapable of integration into almost all socket shapes including long residual limbsFor MyoBock System, 6/7.2 Volt,For integration into all socket shapes, even in cases of long residual limbs. Compared to NiCd battery, these batteries have a lower self-discharge level, higher cell voltage and greater capacity. They have no memory effect.