Skip to main content Skip to search Skip to main navigation

Suction Socket Electrode

Part # Description  

Product information

Electrode cable connection with IDC termination, with 13E206 Electrode Accessories, without electrode cable. Creates an airtight seal between the inner socket and outer socket when embedded into a mounting suspension of elastic material. The Suction Socket Electrode also prevents sweat from penetrating between the outer and inner socket, preventing damage to the electrical and mechanical components caused by corrosion.

The Suction Socket Electrode can not only be used for standard fittings, but is also suitable for application in suction sockets. Combining the suction socket electrode with a 12V10 Tube Valve for a suction socket creates a vacuum effect in the socket, ensuring optimal linkage between the residual limb and the socket.

Shielding and filtering technologies largely protect the 13E202 Suction Socket Electrode against high frequency interference caused by cell phones, walkie-talkies, computers or anti-theft systems in shopping centers so that the correct function of the myoelectrically controlled prosthesis is not affected. The electrode contacts are made from pure titanium and are suitable for people with allergies.

Includes:

  • (1) 13E200 electrode
  • (1) 13E80 adjustment tool
  • (1) 13E191 casting template for inner socket
  • (1) 13E192 lamination template
  • (2) 507S15 lamination plate with bore
  • (1) 13E201 electrode accessories for vacuum-formed inner sockets
  • (2) 503F3 socket screw with Allen head

The following products are also required:

  • 13E129=* electrode cable
HCPCS: L7510
Skip product gallery

Frequently Bought Together

Electrode Cable with Straight Plug and Connector

Electrode Cable with Straight Plug and Connector

Used to connect the electrodes in myoelectric systems to a:9E169 Coaxial Plug13E205 MyoRotronic9E369/9E370 4-in -1 LS Controller or 9E420 7-in-1 Controller13E190 Distributor or 10S7 Electric Wrist Rotator

Tube Valve for Suction Socket

Tube Valve for Suction Socket

The 12V10 suction socket valve allows air to escape from the prosthesis when the residual limb moves within the socket, but prevents air from entering.Used in conjunction with the 13E202 Suction Socket Electrode, the 12V10 Valve:Keeps air out and prevents moisture from leaving the pull-in tubeUses standard pull-in tubes and can be retrofit into existing prosthesisProvides an airtight seal between the inner and outer socket preventing damageCreates optimal linkage between the residual limb and socket by creating a vacuum effect in the suction socket

Electrode Lamination Accessories for Suction Socket Electrode

Electrode Lamination Accessories for Suction Socket Electrode

The Electrode Lamination Accessories for 13E202 Suction Socket Electrode includes lamination dummies for socket and outershell, socket screws, socket washers and sensitivity adjustment tool.Includes:13E203 Lamination Template for Inner Socket13E204 Lamination template for Outer Socket507S15 Lamination Disk, serrated503F3 Socket Screw with Allen head13E80 Sensitivity Adjustment Tool

Silicone Outer Ring

Silicone Outer Ring

The Silicone Outer Ring is an accessory to the Suction Socket Electrode.

Sensitivity Adjustment Tool

Sensitivity Adjustment Tool

The Sensitivity Adjustment Tool is an accessory to the Suction Socket Electrode.

Electrode Bracket Set

Electrode Bracket Set

The Electrode Bracket Set is for positioning and assembling the MyoBock Electrodes in the interim plaster socket or the interim socket of Thermolyn (616T52 or 616T53). It is used with 13E200 electrodes.